MotorCity (Structural) 16 Sep 04 09:48. KarlIt, I would suggest consulting the goal manufacturer to obtain the design loads. The support system will vary among models and manufacturers. This type of loading is not governed by any particular code as it is not a building or structure. That has been my approach for the gymnasium designs in the ...

Engtips. Things To Know About Engtips.

Section 9 (of the 14th edition manual) has a section on coped beam strength. But, it does't talk about the detailing of that cope at all (i.e. rounded vs square). It also has a section on Copes, Blocks and Cuts which talks about the preferred method of sequencing the coping cuts. But, it doesn't talk much about …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members …Petroleum engineering general discussion. (13755 members) forum481 - Professional forum and technical support for engineers for Petroleum engineering general discussion. Includes problem solving collaboration tools. Pipelines, Piping and Fluid Mechanics engineering. forum378 - Professional forum and technical support for engineers for Pipelines, Piping and Fluid Mechanics engineering. Includes problem solving collaboration tools.

It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …

Electronics Packaging engineering. Fluid Power engineering. Gas compression engineering. Gas distribution engineering. Gear & Pulley engineering. Heat Transfer & Thermodynamics engineering. HVAC/R engineering. Ignition, Combustion and Detonation engineering. Laser engineering. Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book.

Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools.Update: My final solution was to drill and epoxy #3 bars at 24" OC (every 3 CMU courses) with 18" of embedment into the existing walls. However, there was an ice storm in late December that revealed more structural problems with the building only to be exacerbated by the winter storm from February.*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Aeronautics & Space Engineers Area. Only the top forums under each …11 Oct 10 01:39. In CMAA 74, paragraph 3.3.2.4.2 states: The localized stresses due to local bending effects imposed by wheel loads calculated at points 0 and 1 are to be combined with the stresses due to the Case 2 loading specified in paragraph 3.3.2.3.2 of this specification. However, it does not explicitly state how they should …

The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites …

Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …

We've been conditioned to tie rewards to travel. But by focusing on rewards beyond travel, we can expand our points and miles freedom. Increased Offer! Hilton No Annual Fee 70K + F...Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for ASME (mechanical) Code Issues. Includes problem solving collaboration tools.Strength (whether for LRFD or ASD) for wind load is checked at a 700 year MRI for RC2 structures while service load is generally taken to be a 10 year MRI. That can be about 58% less load than the strength check. Service loads are somewhat discretionary...IBC has basic deflection calculation requirements, but they are not the end … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... U.S. stocks traded higher this morning, with the Dow Jones gaining more than 100 points on Friday. The Dow traded up 0.41% to 33,473.16 while the... U.S. stocks traded higher this...

Thank you for helping keep Eng-Tips Forums free from inappropriate posts. The Eng-Tips staff will check this out and take appropriate action. Close. Reply To This Thread Posting in the Eng-Tips forums is a member-only feature. Click Here to join Eng-Tips and talk with other members! Already a Member? Login.Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net Joined March 2009. 124 Following. 295 Followers. Tweets & replies. Media.To Remove or insert a Spacer or Blind you first depressurize the System, Then make it Safe. Then you remove all the Bolts on One (1) side of the Flange set. Then you "Jack" the Flanges apart using the built-In Jack Screws (in the Flanges) or with Flange Spreaders (Look it up). Now with the Flanges spread …Water treatment & distribution. (21029 members) forum164 - Professional forum and technical support for engineers for Water treatment & distribution. Includes problem solving collaboration tools. Forum.March 12, 2024. Are you helping your patients with type 1 diabetes make the most of continuous glucose monitoring (CGM) devices? At the Advanced Technologies & …One World Pharma News: This is the News-site for the company One World Pharma on Markets Insider Indices Commodities Currencies Stocks

Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering …

Professional Ethics in engineering. (12071 members) forum765 - Professional forum and technical support for engineers for Professional Ethics in engineering. Includes problem solving collaboration tools. Forum. Search. FAQs. Links. MVPs.4 steps is then only 1750mm clearance and step 5 about 1500mm - too low. Basically you made the hole too small to get the angle of stairs that are suitable for a domestic property ( max angle seems to be about 38 degrees). To get the clearance of 2m under the lip you need about 52-55 degrees.Indian women are more educated than they have ever been. Yet, the latest figures show that fewer of them are working. Indian women are more educated than they have ever been. Yet, ...i have got into trouble with linear gap element. My model like flange contact have 500000 dof. i use linear gap method in axial direction and rbe2 (Fy~Mz) in other direction. unfurtunately, i just obtain some fatal message "fatal message 1012" no matter what i do. (try to change buffsize) or wirte down "nastran system (1015)=1".We calculate the rms value of fault current (If) at the onset of it (t=0sec), using subtransient values of reactances for the sources and taking no account of the dc component. Then, the make current is : 2.55*If. and break current is : 1.255*If. with dc component included in both cases. dpc (Electrical) 23 Jan 02 …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …MVPs. amendale (Structural) (OP) 8 Jan 13 11:42. From reading the AISC 341 it seems to me that an OCBF would almost always be more economicaly feasible versus a SCBF to design due to SCBF capacity design requirements for beams, connections, and columns, as well as compactness restriction for braces. …22 hours ago · The Eng-Tips staff will check this out and take appropriate action. Close. Reply To This Thread Posting in the Eng-Tips forums is a member-only feature. Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search.

Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search.

Brick grows with time, and that can lead to cracking at the thinnest sections, and the two sections in your photos are thin. This cracking in veneer is not indication of settlement or other structural problems, so if it bothers you, get a mason to repoint it. Make sure he knows what he is doing, as amateur repairs can stand out worse than the ...

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Strength (whether for LRFD or ASD) for wind load is checked at a 700 year MRI for RC2 structures while service load is generally taken to be a 10 year MRI. That can be about 58% less load than the strength check. Service loads are somewhat discretionary...IBC has basic deflection calculation requirements, but they are not the end …I want to summarize as follows: Rule 1) The direction of the coordinate axis should align with the direction from "Grid A to Grid B" of the bush element. Rule 2) The "positive" direction of your coordinate system …Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns. Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other users. The targeted audience of Eng-Tips is engineering professionals. 1 day ago · Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... In ASCE 7-22, partially open is included in those. My assumption is that they messed up and forgot to include it in ASCE 7-16. My tin-foil hat opinion: Partially open was added simply because we aren't comfortable labeling buildings that are THAT "open" as "enclosed."

Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search. Strength (whether for LRFD or ASD) for wind load is checked at a 700 year MRI for RC2 structures while service load is generally taken to be a 10 year MRI. That can be about 58% less load than the strength check. Service loads are somewhat discretionary...IBC has basic deflection calculation requirements, but they are not the end …i have got into trouble with linear gap element. My model like flange contact have 500000 dof. i use linear gap method in axial direction and rbe2 (Fy~Mz) in other direction. unfurtunately, i just obtain some fatal message "fatal message 1012" no matter what i do. (try to change buffsize) or wirte down "nastran system (1015)=1".Instagram:https://instagram. facebook marketplace ashland wibigo twittertime and tru tankiniwells fargo bank maryland locations Construction Process2. Construction Process. 2. As a new junior engineer without much construction experience, I wanted to ask whether there is a trustworthy resource which goes into a detailed narrative of the construction process, encompassing from the beginning paperwork, typical teams making up a project, …The caustic scrubber is used to absorb the sour gases like H2S and CO2. To design this, you need to consider the system as an absorption column. For that you need to calculate how many equilibrium stages you have. Do not forget you have , at least, one chemical reaction (H2S + 2NaOH --> Na2S + 2H2O) if your stream doesn't have CO2. mvngokitty megaspo0py kitten leaks ENG-TIPS. ENG-TIPS stands out as one of the most popular portals for engineer communities on the web, and it’s easy to see why. There are over 18 specific …Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. kevin paul dupont twitter Eng-Tips. 291 likes · 1 talking about this. ENG-TIPS FORUMS: GIVING NEW MEANING TO "VALUE ENGINEERING"4 steps is then only 1750mm clearance and step 5 about 1500mm - too low. Basically you made the hole too small to get the angle of stairs that are suitable for a domestic property ( max angle seems to be about 38 degrees). To get the clearance of 2m under the lip you need about 52-55 degrees.